Showing posts with label water carrying capacity of pipe. Show all posts
Showing posts with label water carrying capacity of pipe. Show all posts

Thursday, July 2, 2020

Lateral Length Calculation in Micro Irrigation System

Hi all,

Today I am going to explain an important aspect in micro irrigation system design i.e. Lateral length calculation. 

Lateral length affects mainly for deciding submain position in the field. Over run lateral length might be harmful to the crop because water will not distributed in equal manner in the field. Which ultimately results in poor crop production and loss to the farmer. 

So lets start on how to calculate maximum permissible lateral length in micro irrigation system.

There are several points to be taken in to consideration for calculation of lateral length which are,

- Lateral outer diameter and inner diameter
- Reduction Factor
- Pressure Drop (m/100 m)
- Total Head Loss (m)
- Pressure Variation along with lateral (%)
- Discharge Variation along with lateral (%)


Pressure Drop can be calculated by the Hazen Williams equation as under,









Where,
Flow = Lateral Discharge (lph)
Constant = 140 (hazen williams constant, higher C value = higher smoothness)
Pipe ID = 14.2 mm for 16 mm lateral and 18.2 mm for 20 mm lateral 
Reduction Factor = 0.4 




Total Head Loss can be calculated with below formula,









Pressure Variation along with lateral can be calculated as under,








Flow Variation along with lateral can be calculated by,









Now as we have come to know that how to calculate maximum permissible lateral length, there are some basic rules to taken in to consideration while calculating length of emitting pipe for its optimum working are as under,

Criteria for optimum lateral length,

1. Total Head Loss should not be more than 2 meter in lateral or emitting pipe
2. Pressure Variation should not be more than 20% in lateral 
3. Flow Variation should not be more than 10% in lateral
4. Pressure Loss should not be less than 0.8 m at the end of the lateral  


For ready reference I have created a lateral length table using above mentioned formula.















You can download it from the link below,





or you can calculate all these details with my irrigation details calculator as under,































You can download the calculation sheet from the link below,




Hope this help you guys...

Cheers!!!!


:)











Saturday, November 28, 2015

Water carrying capacity of irrigation pipes

Hi everyone,

Selection of proper pipe size in micro irrigation system (MIS) is very important part.

Today i am going to share some details on water carrying capacity of irrigation pipes,

There are 2 main aspects which affects water carrying capacity of irrigation pipe viz,


  • Pipe Size (i.e. Pipe ID, Pipe OD,Pipe weight,& SDR value of pipe)
  • Velocity 

Lets discuss them in brief,

Pipe Size:
- Pipe size contains certain values like Pipe ID, Pipe Weight, Section Area of pipe etc.
Calculation of the above values can be done as under,


Pipe inside diameter (ID) :






Pipe weight (Wt):








Section Area:







Specific Dimension Ratio (SDR) of pipe:

It's method of rating a pipe's durability against pressure.

Please note that all the calculations are based on SDR 17 as irrigation pipes with this rating are used widely over here in India.

Fluid Flow Velocity in irrigation pipes:
-  The fluid velocity should not exceed to certain limits to avoid noise and damaging wear and tear of pipes & fittings.

Normally velocity in irrigation pipes should be between 1.0 to 2.0 m/sec.

Velocity can be calculated by,











Now with all the above equations you can calculate water carrying capacity of irrigation pipes by the formula below,









Well its a big hectic job to calculate all this....

So I've made an excel sheet for calculating the same in easy way.

 All Calculations are based on pipes with SDR 17.

You can download it from Here (Flow Calculator Download)

Just select pipe size from the drop down list shown as under,



















And then enter velocity in the next cell,















So maximum discharge will be calculated in the cell. For better result and longer lasting age of your micro irrigation system, try to keep flow velocity under 1.5 meter per second.

You can also change the output unit from (m3/hr) to (LPS) by selecting drop down menu as under,


















That's all for water carrying capacity of irrigation pipes.

You can get more information on other aspects of micro irrigation in the links below,


  1. Basic aspects of Micro irrigation system design
  2. Technical aspects of MIS design
  3. Head loss & velocity in irrigation pipes
  4. Video tutorials on Micro irrigation system design
  5. Micro irrigation system components installation
Or Scan a QR code here,



I am a professional trainer for MIS system design, for cost & other information, please contact me on below mail address,

- Hardip Gajjar
  (hrdpgajjar@hotmail.com)